Name | Cooley Tangential Occlusion Clamp |
Lead Time | Lead time advised within 48 hours of order placement. |
Specialty | Cardiothoracic-Cardiovascular Clamps |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | King Plus Surgical Industry |
Sterility | Non-Sterile |
Usage | Reusable |
Cooley Tangential Occlusion Clamp
Cooley Tangential Occlusion Clamp
double angled jaws calibrated at 5.0 mm intervals, 7-3/4″ (19.5 cm)
Cooley Tangential Occlusion Clamp is uniquely designed to clamp vessels in a way that reduces blood flow without completely stopping it in cardiothoracic surgical procedures. This clamp can be best used when doing procedures such as side-by-side anastomosis that required some blood flow. Additionally, this instrument features double angled jaws that are calibrated at 5 mm intervals making it possible to make accurate measurements during the procedure.
SKU:
KPS-04-1036
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Cooley Tangential Occlusion Clamp” Cancel reply
Shipping & Delivery
Related products
Beck Miniature Aorta Clamp – Titanium
Titanium
straight shanks, 6-3/4" (17.0 cm), debakey jaws, titanium
Beck Miniature Aorta clamp is designed for use in cardiothoracic surgeries. This miniature aorta clamp is ideally suited for use in neonatal or pediatric patients who have vessels that are too small to be handled by traditional sized instruments. This instrument can be used to clamp the aorta to occlude blood flow and prevent excessive bleeding during surgery. Additionally, this clamp is available with either DeBakey jaws or titanium jaws.
Cooley Iliac Clamp
Cooley Iliac Clamp
Cooley Iliac Clamp allows for exquisite control of blood flow through large arteries during a number of orthopedic and cardiac procedures, or whenever temporary occlusion of the iliac vasculature is desired. Renowned for its ease of use, Cooley Iliac Clamp is designed for the application of variable pressures on the Iliac artery to prevent intrusive blood flow. It provides for a strong, secure and adjustable grip which can be used for closure of vasculature or secure clamping of soft tissue. The jaws are set at a slight angle so as to allow maneuverability while still maintaining pressure and control when clamping the intended area. This clamp features straight jaws, handles angled at 45 degrees and is available in two different jaws sizes.
Cooley Aortic Aneurysm Clamp
Cooley Aortic Aneurysm Clamp
slightly curved jaws, jaws 7.6 cm, 10-3/4" (27.3 cm)
Cooley Aortic Aneurysm Clamp is made to be used cardiothoracic procedures that require clamping of the aorta, specifically at or around the site of aneurysm. This clamp can be used to in temporary occlusion of the aorta to resect fusiform aneurysms as well as provide additional support and stability in aortic grafting procedures. The slightly curved jaws gives this clamp the ability to contour to and seamlessly move through the surgical field causing the least amount of trauma to the aorta itself and surrounding tissue.
Cooley Miniature Multi Purpose Clamp
Cooley Miniature Multi Purpose Clamp
jaws calibrated at 5.0 mm intervals.
Cooley Miniature Multi Purpose Clamp is well suited for a variety of uses in cardiothoracic surgical procedures. Although this instrument does not have one particularly function but instead is a multi purpose clamp that can be used in a variety of different instances. The miniature size of this clamp makes it more able to reach certain vessels but also makes it better suited for use in smaller patients. This clamp comes equipped with jaws calibrated at 5 mm intervals and is available in three different angles 30, 60 and 90 degrees.
Cooley Coarctation Clamp – 6 3/4″
Cooley Coarctation Clamp - 6 3/4"
jaws calibrated at 5.0 mm intervals, 6-3/4" (17.1 cm
Cooley Coarctation Clamp is made for use in cardiothoracic surgical procedures. The ring handles make this instrument easy to handle and manipulate and the length of the tool allows the handle out of the surgical field. Additionally, the jaws are calibrate at 5.0 mm intervals and this instrument is available with straight shanks and straight, curved or spoon jaws, or angled shanks with straight jaws making it possible to find a suitable instrument for the particular surgical procedure.
Bailey Aorta Clamp
Bailey Aorta Clamp
angled shanks
Bailey Aorta Clamp are designed for use in cardiothoracic surgical procedures. This clamp is ideal for use when there is a surgical maneuver that requires exclusion of a specific portion of the vessel. The unique design of this clamp with the slightly angled shanks allows for this clamp to effectively reach and clamp off the aorta when other instruments may not be able to. Additionally, this instrument is available in three different jaw sizes: extra small, small and large making it well suited for a number of different vessel sizes but also in different levels of blood flow restriction.
Cooley Coarctation Clamp – 9 3/4″
Cooley Coarctation Clamp - 9 3/4"
7.0 cm long straight jaws, straight shanks, 9-3/4" (24.8 cm)
Cooley Coractation Clamp is well suited for use in cardiothoracic surgical procedures that necessitate total or partial occlusion of a vessel. This is often done in cardiothoracic surgical procedures to prevent the patients from losing an excessive amount of blood during surgery. This pattern features longer jaws and a longer overall length for cases where additional reach is necessary, as well as straight jaws and shanks which are designed to provide a firm and stable grip once they have been affixed to the site where the clamping is needed.
Cleveland Clinic Renal Clamp
Cleveland Clinic Renal Clamp
Cleveland Clinic Renal Clamp is a specialized piece of equipment designed for optimal use in cardiothoracic surgical procedures. This clamp is designed for use as a renal clamp to block or reduce blood flow through the renal vessels going to and from the kidney. To accommodate the positioning of these vessels this instrument comes with a significant angle to the jaws making access to the renal vasculature easier. This instrument is available angled either to the left or the right and also comes in either small or large jaws to accommodate a number of different patients sizes.
Reviews
There are no reviews yet.